refrigeration components
     Solenoid Valve (Flare)
     Solenoid Valve (ODF)
     Single Pressure
     Dual Pressure
     Differential Pressure Control
     Filter Drier
     Expansion Valve
     Flow Switch
     Moisture Indicator
     Stop Valve
     Electronic-drain valve
     Auto water trap
     Connetors & tools
     Refrigerant soft hose
     Oil pressure gauge
      pneumatic components
     2W Series Solenoid Valve
     Two-position & Two port Soleno
     SC、SU serial cylinder:
     SDA Serial thin cylinder
     X Series Air Source Processing
     AC1000 Series
     Air source treatment dyad
     Air source treatment triplet
     Directional control valve
     Manually-turn valve
     Shuttle valve
 
     

 

Differential Pressure Control

Differential pressure control is normally used in water system of central air-condition to control the pressure differential between the pipe of water providing & the pipe of water returning. It is different from other pressure differential control, which has a SPDT contact. Through the movement of the floating contact, the control reaches the contact and makes the engine driver to operate the valve. A typical sample of application is to equip the valve in the side pipe near. the system water pump. When the pressure differential between the pipe of water providing & the pipe of water returning is over the pre-set pressure, the valve will open wide, more water goes through the side valve, which will reduce the pressure differential between these two pipes of the water system. On the opposite, the pressure differential will increase between these two pipes of the water system.

For use with fluorinated refrigerants as well as with air and liquid;(Allowable fluid temp.:-45~+120)
Differential pressure of the pressure control is asdjustalbe;
Novel micro-switch ensures reliable switching;
Agile mounting bracket is suitable for different occasions;
It can be used at water system. Reaching to a constant rate of flow through the control of the differential pressure between in & out pipes.
The differential pressure control can be used as protective devices for maintaining oil pressure of compressor for air-conditioning purpose.
The differential pressure have two pattern: Without time setting differential pressure control(frozen water) and with time setting differential pressure control(oil protective) ;
Max working pressure is 33bar.,It is can used as protective the oil filter drier.

 

Specifications:                                               unit: bar

Type

Adjust range

Differential

Factory setting differential

Reset timesec.

M.O.P.

HLD1.5C

0.3~1.5

0.3

0.3

NO

17

HLD2C

0.3~2

0.3

0.5

NO

17

HLD4C

0.5~4

0.5

1

NO

17

HLD4H

2~4

0.5

2

NO

33

HLD6H

2~6

0.5

2

NO

33

HLD4TC

0.5~4

0.5

1

456090

17

HLD4TH

2~4

0.5

2

456090

33

HLD6TH

2~6

0.5

2

456090

33

NoteDifferential pressure control has two protection forms. One is to be off when the differential pressure is lower than the standard and the other is to be off when the differential pressure is higher than the standard

 

 

 

COPYRIGHT © ZHONGZAO Automatic Control Elements Factory
ADD:NO.41 Hengkang,Rd,Fangqiao industry zone, Fenghua City,Zhejiang,China
TEL:86-574-88873770 88873772  FAX:86-574-88848177

E_mail: